6,341 research outputs found
Optical tracker having overlapping reticles on parallel axes Patent
Optical tracker with pair of FM reticles having patterns 90 deg out of phas
Metal Oxide Silicon /MOS/ transistors protected from destructive damage by wire
Loop of flexible, small diameter, nickel wire protects metal oxide silicon /MOS/ transistors from a damaging electrostatic potential. The wire is attached to a music-wire spring, slipped over the MOS transistor case, and released so the spring tensions the wire loop around all the transistor leads, shorting them together. This allows handling without danger of damage
Test apparatus for locating shorts during assembly of electrical buses
A test apparatus is described for locating electrical shorts that is especially suited for use while an electrical circuit is being fabricated or assembled. A ring counter derives input pulses from a square wave oscillator. The outputs of the counter are fed through transistors to an array of light emitting diodes. Each diode is connected to an electrical conductor, such as a bus bar, that is to be tested. In the absence of a short between the electrical conductors the diodes are sequentially illuminated. When a short occurs, a comparator/multivibrator circuit triggers an alarm and stops the oscillator and the sequential energization of the diodes. The two diodes that remain illuminated identify the electrical conductors that are shorted
In-flight friction and wear mechanism
A unique mechanism developed for conducting friction and wear experiments in orbit is described. The device is capable of testing twelve material samples simultaneously. Parameters considered critical include: power, weight, volume, mounting, cleanliness, and thermal designs. The device performed flawlessly in orbit over an eighteen month period and demonstrated the usefulness of this design for future unmanned spacecraft or shuttle applications
Focus drive mechanism for the IUE scientific instrument
A compact, lightweight mechanism was developed for in-orbit adjustment of the position of the secondary mirror (focusing) of the International Ultraviolet Explored telescope. This device is a linear drive with small (.0004 in.) and highly repeatable step increments. Extremely close tolerances are also held in tilt and decentering. The unique mechanization is described with attention to the design details that contribute to positional accuracy. Lubrication, materials, thermal considerations, sealing, detenting against launch loads, and other features peculiar to flight hardware are discussed. The methods employed for mounting the low expansion quartz mirror with minimum distortion are also given
Complex permeability of soft magnetic ferrite polyester resin composites at frequencies above 1 MHz
Composite soft magnetic materials consist of magnetic particles in a non-magnetic matrix. The properties of such materials can be modelled using effective medium theory. Measurements have been made of the complex permeability of composites produced using ferrite powder and polyester resin. The success of various effective medium expressions in predicting the variation of complex permeability with composition has been assessed
Physical outcome measure for critical care patients following intensive care discharge
Introduction: The aim of this study was to evaluate the most suitable
physical outcome measures to be used with critical care patients following
discharge. ICU survivors experience physical problems
such as reduced exercise capacity and intensive care acquired
weakness. NICE guideline ‘Rehabilitation after critical illness’ (1) recommends
the use of outcome measures however does not provide
any specific guidance. A recent Cochrane review noted wide variability
in measures used following ICU discharge (2).
Methods: Discharged ICU patients attended a five week multidisciplinary
programme. Patients’ physical function was assessed during
the programme, at 6 months and 12 months post discharge. Three
outcome measures were included in the initial two cohorts. The Six
Minute Walk Test (6MWT) and the Incremental Shuttle Walk test
(ISWT) were chosen as they have been used within the critical care
follow up setting (2). The Chester Step Test (CST) is widely thought
to be a good indicator of ability to return to work (one of the programmes
primary aims). Ethics approval was waived as the
programme was part of a quality improvement initiative.
Results: Data was collected for the initial patients attending the
programme (n = 13), median age was 52 (IQR = 38-72), median ICU
LOS was 19 days (IQR = 4-91), median APACHE II was 23 (IQR = 19-41)
and 11 were men. One patient was so physically debilitated that the
CST or ISWT could not be completed however a score was achieved
using the 6MWT. Another patient almost failed to achieve level 1 of
the ISWT. Subsequent patients for this project (total n = 47) have all
therefore been tested using the 6MWT. Good inter-rater and intrarater
reliability and validity have been reported for the 6MWT (3).
Conclusions: Exercise capacity measurement is not achievable for
some patients with either the ISWT or the CST due to the severity of
their physical debilitation. Anxiety, post-traumatic stress disorder and
depression are common psychological problems post discharge (4),
therefore using a test with a bleep is not appropriate. Therefore, the 6MWT is the most appropriate physical outcome measure to be used
with critical care patients post discharge
- …